Pandora/DDCSV1.1/RMHV2.1 Configuration Utility

This service uses operational cookies. You have been warned now. Only continue using this service if you are fine with that.
Files uploaded to this service always were and still are only stored temporarily and will be deleted after the generation of the configuration file.
[...] (Show service disclaimer).  The privacy statement of my hosting provider can be found here.

Don't remind me again!

Choosing a starting point

Currently, the default configuration is loaded.

Upload a configuration file to edit: 

The configuration generator is also available in Chinese and partially in Russian.

Don't remind me again!

#DescriptionRange and UnitValue
5 Min. log. radius in 4-axis mode 3.0000 .. 999.9990 mm
6 Rotational ref. axis for A-axis
104 Optimize A-axis path during G0
34 X-axis pulses per mm 50.0000 .. 99999.0000 pulse/mm
35 Y-axis pulses per mm 50.0000 .. 99999.0000 pulse/mm
36 Z-axis pulses per mm 50.0000 .. 99999.0000 pulse/mm
38 A-axis pulses per unit 50.0000 .. 999999.0000
39 A-axis unit
40 A- or B-axis selection
390 X-axis direction electric level
391 Y-axis direction electric level
392 Z-axis direction electric level
393 A-axis direction electric level
418 X-axis pulse signal electric level
419 Y-axis pulse signal electric level
420 Z-axis pulse signal electric level
421 A-axis pulse signal electric level
416 Delay between direction and pulse 0.0000 .. 9999.0000 ns
33 Motor starting speed 0.0000 .. 999.0000 mm/min
100 X-axis speed in manual mode 99.0000 .. 99999.0000 mm/min
101 Y-axis speed in manual mode 99.0000 .. 99999.0000 mm/min
102 Z-axis speed in manual mode 99.0000 .. 99999.0000 mm/min
103 A-axis speed in manual mode 99.0000 .. 99999.0000 deg/min
41 X-axis max. speed in man. mode 99.0000 .. 99999.0000 mm/min
42 Y-axis max. speed in man. mode 99.0000 .. 99999.0000 mm/min
43 Z-axis max. speed in man. mode 99.0000 .. 99999.0000 mm/min
44 A-axis max. speed in man. mode 99.0000 .. 99999.0000 deg/min
45 X-axis start accel. in man. mode 1.0000 .. 9999.0000 mm/s2
46 Y-axis start accel. in man. mode 1.0000 .. 9999.0000 mm/s2
47 Z-axis start accel. in man. mode 1.0000 .. 9999.0000 mm/s2
48 A-axis start accel. in man. mode 1.0000 .. 9999.0000 deg/s2
263 X-axis stop accel. in man. mode 9.0000 .. 9999.0000 mm/s2
264 Y-axis stop accel. in man. mode 9.0000 .. 9999.0000 mm/s2
265 Z-axis stop accel. in man. mode 9.0000 .. 9999.0000 mm/s2
266 A-axis stop accel. in man. mode 9.0000 .. 9999.0000 deg/s2
2020 Jog 1 movement distance 0.0000 .. 999.0000 mm
2021 Jog 2 movement distance 0.0000 .. 999.0000 mm
2022 Jog 3 movement distance 0.0000 .. 999.0000 mm
2023 Jog 4 movement distance 0.0000 .. 999.0000 mm
15 Speed Selection
76 Default operating speed 10.0000 .. 99999.0000 mm/min
99 Operating acceleration 9.0000 .. 9999.0000 mm/s2
80 G0 speed 99.0000 .. 99999.0000 mm/min
77 Maximum speed 99.0000 .. 99999.0000 mm/min
78 Z-axis lifting protection speed 99.0000 .. 99999.0000 mm/min
79 Z-axis dropping protection speed 99.0000 .. 99999.0000
113 Arc-interpolation algorithm
123 Soft-arc algorithm linear error 0.0010 .. 0.1000 mm
124 Circular centrifugal acceleration 0.0000 .. 9999.0000 mm/s2
125 Circular speed adjustment factor 0.1000 .. 2.0000
435 X-axis protection speed 99.0000 .. 99999.0000 mm/min
436 Y-axis protection speed 99.0000 .. 99999.0000 mm/min
82 Z-axis safe height 0.0000 .. 99.0000 mm
89 Z-axis retraction dist. when paused 0.0000 .. 99.0000 mm
395 Enable G53 coordinate system
16 Current coordinate system
219 Stop spindle when program is paused
220 Spindle speed selection source
221 Default spindle speed 10.0000 .. 99999.0000 rpm
98 Maximum spindle speed 99.0000 .. 99999.0000 rpm
227 Spindle electric level
422 Spindle PWM electric level
222 Enable spindle on/off (M3/M5) cmds.
224 Spindle M3/M4/M5 command duration 0.0000 .. 9.0000 s
433 PWM rising rate from 0V to 10V 0.0000 .. 65535.0000
108 Enable M-Bus I/O command
109 M-Bus I/O default state 0.0000 .. 4294967295.0000
228 M8/M9 act. electric level
229 M10/M11 act. electric level
223 Enable M8/M9, M10/M11 commands
225 Duration of M8/M9 commands 0.0000 .. 9.0000 s
226 Duration of M10/M11 commands 0.0000 .. 9.0000 s
49 Homing cycle count 1.0000 .. 5.0000
50 Ignore home sig. when at home
51 Use hard limits for homing
52 Enable X-axis homing function
53 Enable Y-axis homing function
54 Enable Z-axis homing function
55 Enable A-axis homing function
60 X-axis homing electric level
61 Y-axis homing electric level
62 Z-axis homing electric level
63 A-axis homing electric level
64 X-axis homing direction
65 Y-axis homing direction
66 Z-axis homing direction
67 A-axis homing direction
56 X-axis homing speed 99.0000 .. 99999.0000 mm/min
57 Y-axis homing speed 99.0000 .. 99999.0000 mm/min
58 Z-axis homing speed 99.0000 .. 99999.0000 mm/min
59 A-axis homing speed 99.0000 .. 99999.0000 deg/min
83 X-axis back distance after homing 0.0000 .. 99.0000 mm
84 Y-axis back distance after homing 0.0000 .. 99.0000 mm
85 Z-axis back distance after homing 0.0000 .. 99.0000 mm
86 A-axis back distance after homing 0.0000 .. 360.0000 deg
126 Home after booting
116 X-axis zero signal source
117 Y-axis zero signal source
118 Z-axis zero signal source
119 A-axis zero signal source
68 Tool setting function mode
70 Probe signal electric level
69 Thickness of tool sensor -99.0000 .. 99.0000 mm
71 Initial tool position
72 Initial probe position on X-axis -9999.0000 .. 9999.0000 mm
73 Initial probe position on Y-axis -9999.0000 .. 9999.0000 mm
74 Initial probe position on Z-axis -9999.0000 .. 9999.0000 mm
75 Retraction distance after probe 0.0000 .. 99.0000 mm
2000 Cutter diameter 0.0000 .. 999.0000 mm
2001 Toolplate X-thickness 0.0000 .. 999.0000 mm
2002 Toolplate Y-thickness 0.0000 .. 999.0000 mm
2003 Toolplate Z-thickness 0.0000 .. 999.0000 mm
2004 X-axis shift before probed -999.0000 .. 999.0000 mm
2005 Y-axis shift before probed -999.0000 .. 999.0000 mm
2006 Z-position before X(Y)-axis probed -999.0000 .. 999.0000 mm
2007 Tool retraction touching X-axis 0.0000 .. 999.0000 mm
2008 Tool retraction touching Y-axis 0.0000 .. 999.0000 mm
2009 Tool retraction touching Z-axis 0.0000 .. 999.0000 mm
2010 Center of toolplate 0.0000 .. 999.0000 mm
2011 Probing feedrate 10.0000 .. 999.0000 mm/min
400 Enable neg. X-axis hard limit
401 Enable neg. Y-axis hard limit
402 Enable neg. Z-axis hard limit
403 Enable neg. A-axis hard limit
404 Enable pos. X-axis hard limit
405 Enable pos. Y-axis hard limit
406 Enable pos. Z-axis hard limit
407 Enable pos. A-axis hard limit
408 El. level of X-axis neg. hard limit
409 El. level of Y-axis neg. hard limit
410 El. level of Z-axis neg. hard limit
411 El. level of A-axis neg. hard limit
412 El. level of X-axis pos. hard limit
413 El. level of Y-axis pos. hard limit
414 El. level of Z-axis pos. hard limit
415 El. level of A-axis pos. hard limit
374 Enable software limits
375 Negative X-axis software limit -9999.0000 .. 9999.0000 mm
376 Negative Y-axis software limit -9999.0000 .. 9999.0000 mm
377 Negative Z-axis software limit -9999.0000 .. 9999.0000 mm
378 Negative A-axis software limit -9999.0000 .. 9999.0000 deg
379 Positive X-axis software limit -9999.0000 .. 9999.0000 mm
380 Positive Y-axis software limit -9999.0000 .. 9999.0000 mm
381 Positive Z-axis software limit -9999.0000 .. 9999.0000 mm
382 Positive A-axis software limit -9999.0000 .. 9999.0000 deg
430 MPG interface type
431 MPG precision 0.0010 .. 0.0100
432 Standard MPG electric signal level
428 Enable ESTOP signal on MPG
429 Electric level of ESTOP on MPG
434 MPG A/B phase signal level
448 Enable MPG control
423 Enable ext. ESTOP signal
424 Electric signal level of ext. ESTOP signal
425 Enable extended start and pause
426 Electric signal level of ext. START
427 Electric signal level of ext. PAUSE
446 Function of ext. key 1
447 Function of ext. key 2
437 Enable X-axis backlash
438 Enable Y-axis backlash
439 Enable Z-axis backlash
440 Enable A-axis backlash
441 X-axis backlash distance 0.0000 .. 0.9990 mm
442 Y-axis backlash distance 0.0000 .. 0.9990 mm
443 Z-axis backlash distance 0.0000 .. 0.9990 mm
444 A-axis backlash distance 0.0000 .. 9.9990 deg
445 Backlash speed 99.0000 .. 99999.0000 mm/min
267 H00 tool offset -999.9990 .. 999.9990 mm
268 H01 tool offset -999.9990 .. 999.9990 mm
269 H02 tool offset -999.9990 .. 999.9990 mm
270 H03 tool offset -999.9990 .. 999.9990 mm
271 H04 tool offset -999.9990 .. 999.9990 mm
272 H05 tool offset -999.9990 .. 999.9990 mm
273 H06 tool offset -999.9990 .. 999.9990 mm
274 H07 tool offset -999.9990 .. 999.9990 mm
275 H08 tool offset -999.9990 .. 999.9990 mm
276 H09 tool offset -999.9990 .. 999.9990 mm
277 H10 tool offset -999.9990 .. 999.9990 mm
278 H11 tool offset -999.9990 .. 999.9990 mm
279 H12 tool offset -999.9990 .. 999.9990 mm
280 H13 tool offset -999.9990 .. 999.9990 mm
281 H14 tool offset -999.9990 .. 999.9990 mm
282 H15 tool offset -999.9990 .. 999.9990 mm
283 D00 tool offset -999.9990 .. 999.9990 mm
284 D01 tool offset -999.9990 .. 999.9990 mm
285 D02 tool offset -999.9990 .. 999.9990 mm
286 D03 tool offset -999.9990 .. 999.9990 mm
287 D04 tool offset -999.9990 .. 999.9990 mm
288 D05 tool offset -999.9990 .. 999.9990 mm
289 D06 tool offset -999.9990 .. 999.9990 mm
290 D07 tool offset -999.9990 .. 999.9990 mm
291 D08 tool offset -999.9990 .. 999.9990 mm
292 D09 tool offset -999.9990 .. 999.9990 mm
293 D10 tool offset -999.9990 .. 999.9990 mm
294 D11 tool offset -999.9990 .. 999.9990 mm
295 D12 tool offset -999.9990 .. 999.9990 mm
296 D13 tool offset -999.9990 .. 999.9990 mm
297 D14 tool offset -999.9990 .. 999.9990 mm
298 D15 tool offset -999.9990 .. 999.9990 mm
1 Language
2 Display refresh delay during op. 400.0000 .. 10000.0000
3 Tool path button function
114 Jog enabled in continuous mode
115 Metric or imperial units
120 USB-stick partition
218 Cycle start button mode
499 User access key 0.0000 .. 999999.0000
396 Max. polyline segments 100.0000 .. 3600.0000
495 Interpolation period 0.0020 .. 0.0100 s
250 Enable realtime toolpath
253 Toolpath mode
88 Enable buzzer feedback

If you find this utility useful and it saved you time and you want to keep it online, please consider giving back (opens in new tab).