Pandora/DDCSV1.1/2.1/3.1/RMHVx.1 Configuration Utility

This service uses operational cookies. You have been warned now. Only continue using this service if you are fine with that.
Files uploaded to this service are always only stored temporarily and will be deleted after the generation of the configuration file.

Disclaimer:
“THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.” (Quote from the BSD-license)

The privacy statement of my hosting provider can be found here.

Don't remind me again!

Edit existing configuration

The default configuration was loaded.

Upload a configuration file to edit: 

The configurator has been updated to support the latest 2020 firmware for DDCSV1.1, DDCSV2.1 and DDCSV3.1!

Something is broken or you prefered the old version? Contact us or click here for the original version.

The configuration generator is also available in Russian (русский) and partially in Chinese (中文).

Don't remind me again!

#DescriptionRange and UnitValue
5 Minimum log radius of 4axis machining 0.1000 .. 999.9990 unit
6 A axis rotate reference axis
104 A axis optimal path when G0 run
115 Unit selection
2047 IO output M command execution strategy
34 X axis pulse equivalency 50.0000 .. 99999.0000 P/unit
35 Y axis pulse equivalency 50.0000 .. 99999.0000 P/unit
36 Z axis pulse equivalency 50.0000 .. 99999.0000 P/unit
38 A axis pulse equivalency 20.0000 .. 999999.0000
39 A axis pulse unit
40 AB axis Selection
230 X-axis command type
231 Y-axis command type
232 Z-axis command type
233 A-axis command type
234 X-axis DIR in A/B phase mode
235 Y-axis DIR in A/B phase mode
236 Z-axis DIR in A/B phase mode
237 A-axis DIR in A/B phase mode
390 X axis DIR signal Electric Level
391 Y axis DIR signal Electric Level
392 Z axis DIR signal Electric Level
393 A axis DIR signal Electric Level
418 X axis Pulse signal Electric Level
419 Y axis Pulse signal Electric Level
420 Z axis Pulse signal Electric Level
421 A axis Pulse signal Electric Level
416 Time interval between DIR & pulse 0.0000 .. 9999.0000 ns
33 Motor start speed 0.0000 .. 999.0000 unit/min
100 X axis manual control speed 1.0000 .. 99999.0000 unit/min
101 Y axis manual control speed 1.0000 .. 99999.0000 unit/min
102 Z axis manual control speed 1.0000 .. 99999.0000 unit/min
103 A axis manual control speed 99.0000 .. 99999.0000 deg/min
41 X Axis max speed in M_Ctrl mode 99.0000 .. 99999.0000 unit/min
42 Y Axis max speed in M_Ctrl mode 99.0000 .. 99999.0000 unit/min
43 Z Axis max speed in M_Ctrl mode 99.0000 .. 99999.0000 unit/min
44 A Axis max speed in M_Ctrl mode 99.0000 .. 99999.0000 deg/min
45 X axis start Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
46 Y axis start Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
47 Z axis start Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
48 A axis start Acc in M_Ctrl mode 1.0000 .. 9999.0000 deg/s2
263 X axis stop Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
264 Y axis stop Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
265 Z axis stop Acc in M_Ctrl mode 0.3000 .. 9999.0000 unit/s2
266 A axis stop Acc in M_Ctrl mode 9.0000 .. 9999.0000 deg/s2
2020 Jog-1 moving distance 0.0000 .. 999.0000 unit
2021 Jog-2 moving distance 0.0000 .. 999.0000 unit
2022 Jog-3 moving distance 0.0000 .. 999.0000 unit
2023 Jog-4 moving distance 0.0000 .. 999.0000 unit
15 Speed Selection
76 Default operation speed 1.0000 .. 99999.0000 unit/min
99 Operation acceleration 0.3000 .. 9999.0000 unit/s2
80 G0 Speed 1.0000 .. 99999.0000 unit/min
77 Maximum speed 99.0000 .. 99999.0000 unit/min
78 Z axis lifting protection speed 1.0000 .. 99999.0000 unit/min
79 Z axis dropping protection speed 1.0000 .. 99999.0000 unit/min
113 Arc interpolation algorithm selection
123 Soft arc algorithm chord error 0.0010 .. 0.1000 mm
124 Circular centrifugal acceleration 0.0000 .. 9999.0000 unit/s2
125 Circular speed adjustment factor 0.1000 .. 2.0000
435 X axis protection speed 1.0000 .. 99999.0000 unit/min
436 Y axis protection speed 1.0000 .. 99999.0000 unit/min
82 Z axis safe height 0.0000 .. 99.0000 unit
89 Z axis back distance when pause 0.0000 .. 99.0000 unit
2031 Uniaxial acc is limited by M_Ctrl start acc
2037 Is FRO valid for G0?
2041 G53/G153 function interchange
2043 Subroutine programming mode
395 Support of G53 coordinate sys
16 Current coordinate system
219 Stop Spindle when paused
220 Spindle speed selection
221 Default spindle speed 10.0000 .. 99999.0000 rpm
98 Maximum spindle speed 99.0000 .. 99999.0000 rpm
227 Spindle switch Active level
422 definition of PWM Electric level
222 Spindle commands M3/M5 response
224 Spindle M3/M4/M5 response Duration 0.0000 .. 9.0000 s
433 PWM rising rate from 0V to 10V 0.0000 .. 65535.0000
2045 M4 prot definition
108 M Bus IO command response
109 M Bus IO default status 0.0000 .. 4294967295.0000
110 M Bus IO Initialization strategy
228 M8/M9 active electric level
229 M10/M11 active electric level
223 Response of M code(M8/M9,M10/M11)
225 Delay time of M8/M9 0.0000 .. 9.0000 s
226 Delay time of M10/M11 0.0000 .. 9.0000 s
49 HOME times 1.0000 .. 5.0000
50 HOME signal Effective when HOME
51 Enable limit signal when HOME
52 Enable X Home Searching function
53 Enable Y Home Searching function
54 Enable Z Home Searching function
55 Enable A Home Searching function
60 X axis Home signal Electric Level
61 Y axis Home signal Electric Level
62 Z axis Home signal Electric Level
63 A axis Home signal Electric Level
64 X axis Home direction
65 Y axis Home direction
66 Z axis Home direction
67 A axis Home direction
56 X axis Home speed 1.0000 .. 99999.0000 unit/min
57 Y axis Home speed 1.0000 .. 99999.0000 unit/min
58 Z axis Home speed 1.0000 .. 99999.0000 unit/min
59 A axis Home speed 99.0000 .. 99999.0000 deg/min
83 X axis back distance after Home 0.0000 .. 99.0000 unit
84 Y axis back distance after Home 0.0000 .. 99.0000 unit
85 Z axis back distance after Home 0.0000 .. 99.0000 unit
86 A axis back distance after Home 0.0000 .. 360.0000 deg
126 Home reminder after booting
116 X-axis zero signal source select
117 Y-axis zero signal source select
118 Z-axis zero signal source select
119 A-axis zero signal source select
2024 X axis Home offset -999.0000 .. 999.0000 unit
2025 Y axis Home offset -999.0000 .. 999.0000 unit
2026 Z axis Home offset -999.0000 .. 999.0000 unit
2027 A axis Home offset -999.0000 .. 999.0000 deg
2048 Home sequence
68 Tool Setting function mode
70 Probe signal electric level
69 Thickness of tool sensor -99.0000 .. 99.0000 unit
71 Initial tool's position
72 Initial probe position on X axis -9999.0000 .. 9999.0000 unit
73 Initial probe position on Y axis -9999.0000 .. 9999.0000 unit
74 Initial probe position on Z axis -9999.0000 .. 9999.0000 unit
75 Back distance after probe 0.0000 .. 99.0000 unit
2000 Cutter diameter 0.0000 .. 999.0000 unit
2001 Tool plate thick for X 0.0000 .. 999.0000 unit
2002 Tool plate thick for Y 0.0000 .. 999.0000 unit
2003 Tool plate thick for Z 0.0000 .. 999.0000 unit
2004 Shift of X axis before probed -999.0000 .. 999.0000 unit
2005 Shift of Y axis before probed -999.0000 .. 999.0000 unit
2006 Z position before X(Y)-axis probed -999.0000 .. 999.0000 unit
2007 Back distance when the tool touches the X-axis edge 0.0000 .. 999.0000 unit
2008 Back distance when the tool touches the Y-axis edge 0.0000 .. 999.0000 unit
2009 Back distance when the tool touches the Z-axis edge 0.0000 .. 999.0000 unit
2010 Center of tool plate 0.0000 .. 999.0000 unit
2011 Probe feedrate 1.0000 .. 999.0000 unit/min
400 Limited siganl active of X--
401 Limited siganl active of Y--
402 Limited siganl active of Z--
403 Limited siganl active of A--
404 Limited siganl active of X++
405 Limited siganl active of Y++
406 Limited siganl active of Z++
407 Limited siganl active of A++
408 Effective electric level of X--
409 Effective electric level of Y--
410 Effective electric level of Z--
411 Effective electric level of A--
412 Effective electric level of X++
413 Effective electric level of Y++
414 Effective electric level of Z++
415 Effective electric level of A++
374 Enable software limit
375 Soft-limited postion value of X-- -9999.0000 .. 9999.0000 unit
376 Soft-limited postion value of Y-- -9999.0000 .. 9999.0000 unit
377 Soft-limited postion value of Z-- -9999.0000 .. 9999.0000 unit
378 Soft-limited postion value of A-- -9999.0000 .. 9999.0000 deg
379 Soft-limited postion value of X++ -9999.0000 .. 9999.0000 unit
380 Soft-limited postion value of Y++ -9999.0000 .. 9999.0000 unit
381 Soft-limited postion value of Z++ -9999.0000 .. 9999.0000 unit
382 Soft-limited postion value of A++ -9999.0000 .. 9999.0000 deg
2030 Soft-limited stop mode
2032 Soft-limited pre-judgment coefficient of X 0.5000 .. 2.0000
2033 Soft-limited pre-judgment coefficient of Y 0.5000 .. 2.0000
2034 Soft-limited pre-judgment coefficient of Z 0.5000 .. 2.0000
2035 Soft-limited pre-judgment coefficient of A 0.5000 .. 2.0000
2038 Enable software limit alarm in the idle state
430 MPG interface type
431 MPG Precision 0.0010 .. 0.0100
432 Standard MPG signal Electric Level
428 Enable the ESTOP signal on MPG
429 Electric level of ESTOP on MPG
434 A/B phase signal level on MPG
448 MPG control mode
2028 The percentage of the change in value per X Pulses of the Handwheel 1.0000 .. 100.0000
2044 The initial state of manual mode is MPG
423 Enable signal of extended ESTOP
424 Electric level of ext-ESTOP signal
425 Enable extended START&PAUSE
426 Electric level of Ext-key1
427 Electric level of Ext-key2
446 Define the Function of Ext-key1
447 Define the Function of Ext-key2
2046 Extended function key filter coefficient 0.0000 .. 20.0000
437 Enable of X axis backlash
438 Enable of Y axis backlash
439 Enable of Z axis backlash
440 Enable of A axis backlash
441 X axis backlash distance 0.0000 .. 0.9990 unit
442 Y axis backlash distance 0.0000 .. 0.9990 unit
443 Z axis backlash distance 0.0000 .. 0.9990 unit
444 A axis backlash distance 0.0000 .. 9.9990 deg
267 H00 tool offset -999.9990 .. 999.9990 unit
268 H01 tool offset -999.9990 .. 999.9990 unit
269 H02 tool offset -999.9990 .. 999.9990 unit
270 H03 tool offset -999.9990 .. 999.9990 unit
271 H04 tool offset -999.9990 .. 999.9990 unit
272 H05 tool offset -999.9990 .. 999.9990 unit
273 H06 tool offset -999.9990 .. 999.9990 unit
274 H07 tool offset -999.9990 .. 999.9990 unit
275 H08 tool offset -999.9990 .. 999.9990 unit
276 H09 tool offset -999.9990 .. 999.9990 unit
277 H10 tool offset -999.9990 .. 999.9990 unit
278 H11 tool offset -999.9990 .. 999.9990 unit
279 H12 tool offset -999.9990 .. 999.9990 unit
280 H13 tool offset -999.9990 .. 999.9990 unit
281 H14 tool offset -999.9990 .. 999.9990 unit
282 H15 tool offset -999.9990 .. 999.9990 unit
283 D00 tool offset -999.9990 .. 999.9990 unit
284 D01 tool offset -999.9990 .. 999.9990 unit
285 D02 tool offset -999.9990 .. 999.9990 unit
286 D03 tool offset -999.9990 .. 999.9990 unit
287 D04 tool offset -999.9990 .. 999.9990 unit
288 D05 tool offset -999.9990 .. 999.9990 unit
289 D06 tool offset -999.9990 .. 999.9990 unit
290 D07 tool offset -999.9990 .. 999.9990 unit
291 D08 tool offset -999.9990 .. 999.9990 unit
292 D09 tool offset -999.9990 .. 999.9990 unit
293 D10 tool offset -999.9990 .. 999.9990 unit
294 D11 tool offset -999.9990 .. 999.9990 unit
295 D12 tool offset -999.9990 .. 999.9990 unit
296 D13 tool offset -999.9990 .. 999.9990 unit
297 D14 tool offset -999.9990 .. 999.9990 unit
298 D15 tool offset -999.9990 .. 999.9990 unit
1 Language setting
2 Display response during working 400.0000 .. 10000.0000
3 Function of tool path key
114 Jog support in continuous mode
120 U disk partition type
218 Cycle Start key mode selection
499 user access key 0.0000 .. 999999.0000
396 Number of line 100.0000 .. 3600.0000
495 Interpolation period 0.0020 .. 0.0100 s
250 Real track paint enable
253 Track paint mode
238 IO input filter time width 0.0010 .. 9999.9990 ms
88 Enable of beep
2029 Color reversal
18 Artboard width 0.0000 .. 9999.9990
19 Artboard height 0.0000 .. 9999.9990
20 Sketchpad thickness 0.0000 .. 9999.9990
192 Artboard zero point X position 0.0000 .. 9999.9990
193 Artboard zero point Y position 0.0000 .. 9999.9990
194 Artboard zero point Z position 0.0000 .. 9999.9990
2036 Automatically adjust the artboard
2039 Specified line scan increment 0.0000 .. 1000.0000
2042 Whether all-zero op. contains the Z-axis